{"title":"Boom Testing","description":null,"products":[{"product_id":"sentinel-leakage-current-monitor-c4070025","title":"Sentinel Leakage-Current Monitor","description":"\u003cp\u003eTo alert utility-line workers of overcurrent conditions on such aerial devices as insulated ladders and truck booms, the Sentinel sounds an alarm if leakage current reaches a pre-set level.\u003c\/p\u003e\n\u003cp\u003eThe leakage setting adjusts from 1 to 1,000 microamperes in resolution increments of 0.1 microamp.\u003c\/p\u003e\n\u003cp\u003eThe audible warning eliminates the need to watch the actual current level, continuously displayed on the Sentinel’s digital LCD screen.\u003c\/p\u003e\n\u003cp\u003eThe alarm sounds immediately upon overcurrent and continues until the condition is corrected. To also trigger a truck horn or other external alarm, a jack on the instrument panel accepts a standard 1\/4\" two-conductor phone plug.\u003c\/p\u003e\n\u003cp\u003eA test terminal on the panel permits a simple continuity check of the monitor leads prior to each operation.\u003c\/p\u003e\n\u003cp\u003eBefore each use, the instrument automatically performs a rapid electronic self test. Simple operating steps are printed on the inside lid panel. A detailed instruction sheet also comes with each unit.\u003c\/p\u003e","brand":"Chance","offers":[{"title":"Default Title","offer_id":50256116285761,"sku":"HUB-C4070025","price":7839.15,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0743\/6959\/7761\/files\/HPS_ID_C4070025_PRODIMAGE_1200.png?v=1741128868"},{"product_id":"von-bcm-44b-6-bcm-series-of-boom-current-monitors","title":"BCM Series of Boom Current Monitors","description":"\u003cp class=\"custom_info\"\u003eBare-Hand Live-Line Work Safety\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRugged, Dependable Design\u003cbr\u003eAutomatic Safety Check for grounded test cables\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BCM-44 and BCM-44B are state of the art current monitors designed for continuous operation during bare-hand work. The BCM has an adjustable set point (5 presets also available on BCM-44B) between 1 and 400 microamperes AC or DC. A 90-dB horn sounds an audible warning if this current set point is ever exceeded during use.\u003c\/p\u003e\n\u003cp\u003eThe BCM-44 and BCM-44B are extremely rugged and dependable current monitors. Designed for operation a variety of weather conditions, the BCM provides the security needed for bare-hand live-line work.\u003c\/p\u003e\n\u003ch4\u003eAdditional Features of the BCM 44B:\u003c\/h4\u003e\n\u003cp\u003e1. Metering of test circuit for boom metering bands\u003cbr\u003e2. Metering of test circuit for hoses\u003cbr\u003e3. Metering of test circuit for leveling rods or fiber optics\u003cbr\u003e4. Total test including the sum of all three circuits\u003cbr\u003e5. Band mis-wiring detection during power-up test.\u003c\/p\u003e\n\u003cdiv\u003eNote: Daily use of this monitor does not eliminate the need to perform periodic over-voltage tests on aerial lift devices. The absolute minimum recommended over-voltage test should be a DC test of 2.1 times the line to ground exposure or an AC test of 1.5 times the line to ground exposure.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv class=\"dt-layout-row dt-layout-table\"\u003e\n\u003cdiv class=\"dt-layout-cell  dt-layout-full\"\u003e\n\u003ctable style=\"width: 100%; height: 529.031px;\" aria-describedby=\"tablepress-4_info\" class=\"tablepress tablepress-id-4 dataTable\" id=\"tablepress-4\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 17.87%;\" data-dt-column=\"0\"\u003e\n\u003ccol style=\"width: 40.7942%;\" data-dt-column=\"1\"\u003e\n\u003ccol style=\"width: 40.7942%;\" data-dt-column=\"2\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\" class=\"row-1\"\u003e\n\u003ctd style=\"height: 19.5938px;\" colspan=\"1\" rowspan=\"1\" data-dt-column=\"0\" data-title=\"BCM-44\" class=\"column-1 dt-orderable-asc dt-orderable-desc\"\u003e\n\u003cspan class=\"dt-column-title\"\u003eBCM-44\u003c\/span\u003e\u003cspan aria-label=\"BCM-44: Activate to sort\" role=\"button\" class=\"dt-column-order\" tabindex=\"0\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003cth style=\"height: 19.5938px;\" aria-sort=\"ascending\" colspan=\"1\" rowspan=\"1\" data-dt-column=\"1\" class=\"column-2 dt-orderable-asc dt-orderable-desc dt-ordering-asc\"\u003e\n\u003cspan class=\"dt-column-title\"\u003eBCM-44\u003c\/span\u003e\u003cspan aria-label=\"BCM-44: Activate to invert sorting\" role=\"button\" class=\"dt-column-order\" tabindex=\"0\"\u003e\u003c\/span\u003e\n\u003c\/th\u003e\n\u003cth style=\"height: 19.5938px;\" colspan=\"1\" rowspan=\"1\" data-dt-column=\"2\" class=\"column-3 dt-orderable-asc dt-orderable-desc\"\u003e\n\u003cspan class=\"dt-column-title\"\u003eBCM-44B\u003c\/span\u003e\u003cspan aria-label=\"BCM-44B: Activate to sort\" role=\"button\" class=\"dt-column-order\" tabindex=\"0\"\u003e\u003c\/span\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-striping row-hover\"\u003e\n\u003ctr style=\"height: 39.1875px;\" class=\"row-3\"\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"BCM-44\" class=\"column-1\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"BCM-44B\" class=\"column-2\"\u003e0-400 microamperes AC or DC 1 microampere resolution\u003c\/td\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"\" class=\"column-3\"\u003e0-400 microamperes AC or DC 1 microampere resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.375px;\" class=\"row-9\"\u003e\n\u003ctd style=\"height: 78.375px;\" data-title=\"BCM-44\" class=\"column-1\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd style=\"height: 78.375px;\" data-title=\"BCM-44B\" class=\"column-2\"\u003e12 or 24 volts D.C., negative ground, draws 0.3 A (0.5 A @ 24V) with horn sounding and 0.06 A\u003cbr\u003eunder normal operation.\u003c\/td\u003e\n\u003ctd style=\"height: 78.375px;\" data-title=\"\" class=\"column-3\"\u003e12 or 24 volts D.C., negative ground, draws 0.3 A (0.5 A @ 24V) with horn sounding and 0.06 A\u003cbr\u003eunder normal operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\" class=\"row-14\"\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"BCM-44\" class=\"column-1\"\u003eTest Cable\u003c\/td\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"BCM-44B\" class=\"column-2\"\u003e25’ (7.6m) shielded coaxial cable provided\u003c\/td\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"\" class=\"column-3\"\u003e4’ (1.2m) shielded six conductor cable provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\" class=\"row-15\"\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"BCM-44\" class=\"column-1\"\u003ePower Cable\u003c\/td\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"BCM-44B\" class=\"column-2\"\u003e4’ (1.2m) three conductor cable provided\u003c\/td\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"\" class=\"column-3\"\u003e4’ (1.2m) three conductor cable provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\" class=\"row-11\"\u003e\n\u003ctd style=\"height: 19.5938px;\" data-title=\"BCM-44\" class=\"column-1\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\" data-title=\"BCM-44B\" class=\"column-2\"\u003e5 Lbs. (2.3kg)\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\" data-title=\"\" class=\"column-3\"\u003e5 Lbs. (2.3kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 117.562px;\" class=\"row-6\"\u003e\n\u003ctd style=\"height: 117.562px;\" data-title=\"BCM-44\" class=\"column-1\"\u003eSet Point(s)\u003c\/td\u003e\n\u003ctd style=\"height: 117.562px;\" data-title=\"BCM-44B\" class=\"column-2\"\u003eControls allow selection of six presets (27, 40, 66, 93, 133, 289 microamperes) or dial adjustable position\u003cbr\u003evariable from 5 to 500 microamperes.\u003c\/td\u003e\n\u003ctd style=\"height: 117.562px;\" data-title=\"\" class=\"column-3\"\u003eControls allow selection of six presets (27, 40, 66, 93, 133, 289 microamperes) or dial adjustable position\u003cbr\u003evariable from 5 to 500 microamperes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\" class=\"row-13\"\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"BCM-44\" class=\"column-1\"\u003eInput for Power\u003c\/td\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"BCM-44B\" class=\"column-2\"\u003eFlange mounted 3 pin Amphenol receptacle with cap\u003c\/td\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"\" class=\"column-3\"\u003eFlange mounted 3 pin Amphenol receptacle with cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.375px;\" class=\"row-8\"\u003e\n\u003ctd style=\"height: 78.375px;\" data-title=\"BCM-44\" class=\"column-1\"\u003eAudible Alarm\u003c\/td\u003e\n\u003ctd style=\"height: 78.375px;\" data-title=\"BCM-44B\" class=\"column-2\"\u003eInternal 90dB vibrating horn sounds when current exceeds set point, or when measuring lead\u003cbr\u003eis accidentally grounded.\u003c\/td\u003e\n\u003ctd style=\"height: 78.375px;\" data-title=\"\" class=\"column-3\"\u003eInternal 90dB vibrating horn sounds when current exceeds set point, or when measuring lead\u003cbr\u003eis accidentally grounded.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\" class=\"row-4\"\u003e\n\u003ctd style=\"height: 19.5938px;\" data-title=\"BCM-44\" class=\"column-1\"\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\" data-title=\"BCM-44B\" class=\"column-2\"\u003eLess than 0.5 volts full scale\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px;\" data-title=\"\" class=\"column-3\"\u003eLess than 0.5 volts full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\" class=\"row-2\"\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"BCM-44\" class=\"column-1\"\u003eDisplay Type\u003c\/td\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"BCM-44B\" class=\"column-2\"\u003eLiquid crystal display w\/ heater Digits are 0.75 inches (2 cm)\u003c\/td\u003e\n\u003ctd style=\"height: 39.1875px;\" data-title=\"\" class=\"column-3\"\u003eLiquid crystal display w\/ heater Digits are 0.75 inches (2 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"The Von Corporation","offers":[{"title":"BCM-44","offer_id":68266493935937,"sku":"VON-BCM-44","price":0.0,"currency_code":"CAD","in_stock":true},{"title":"BCM-44B","offer_id":68266493968705,"sku":"VON-BCM-44B","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0743\/6959\/7761\/files\/11.jpg?v=1794581535"}],"url":"https:\/\/linestar.ca\/collections\/boom-testing.oembed","provider":"LineStar Utility Supply","version":"1.0","type":"link"}