Skip to content

Qualstik Live-Line Power Quality Meter

Request a quote

The Qualstik Power Quality Meter has been developed specifically for measurement of four important items of power quality in the electric utility industry. These are Current, True Power Factor, Total Harmonic Distortion and the Direction of Current Flow.

The Qualstik is an excellent survey instrument for locating problem areas for comprehensive testing. The SensorLink patented amp sensor does not use magnetic materials and has no moving parts. The opening of the sensor is electronically closed and external currents are electronically rejected. The True Power Factor is calculated by measuring the electric field in comparison with the current reported from the amp sensor.

The Qualstik is not position sensitive, just slip it over a conductor and touch the electrode in the bottom of the fork to the line. The meter will store and calculate the three measurements within 10 seconds. The current reading is shown on one line of the display while the power factor and THD readings share the other line. The direction of current flow indication shows below the other readings on the display.

The housing of the Qualstiks are made of urethane and built to operate safely even in severe utility environments. They are resistant to shock, water repellent, and unsusceptible to flame. They also operate in a wide temperature environment.

The Qualstik is an excellent survey tool to assist determining placement of power factor correction devices as well as identifying other power quality problems. 

The QualstikPlus is designed to store up to eight sets of readings, which the user is then able to delete on the instrument.

Spec Sheets

View Qualstik Plus Specification

Specification Details
Model Number 8-061 XT PLUS / 8-062 PLUS
Description Qualstik Plus / Wide Jaw Qualstik Plus
Sensor Opening 8-061 XT PLUS: 2.5 in, 6.35 cm
8-062 PLUS: 3.86 in, 9.8 cm
Weight 8-061 XT PLUS: 3.0 lbs, 1.37 kg
8-062 PLUS: 3.5 lbs, 1.58 kg
Frequency, 50 Hz 47 to 53 Hz
Frequency, 60 Hz 57 to 63 Hz
Measurements Nine Readings
Range of Operation – True RMS Amps 1-2000 A (5-2000A for the 8-062 PLUS)
Range of Operation – Power Factor 0.01 lag to 0.01 Lead
Range of Operation – THD Amps 1-100%
Range of Operation – Current Flow Direction Amps in or Amps Out
Range of Operation – Voltage phase to phase 600 Volts to 500kV
Resolution – Amps 1-99.9A 0.1 A
Resolution – Amps 100-2000A 1 A
Resolution – Power Factor 1.0 to .01
Resolution – THD Amps 0.1% to 10% 0.1%
Resolution – > 10% 1.0%
Accuracy – Amps ± 1%, ± 2 Counts
Accuracy – Power Factor ±.01 from .71 lead to .71 lag
Accuracy – THD Amps ±1% from 0 to 25%
EEC Standards Successfully passed international test standards indicated by CE
Mechanical – Controls Single button operation
Mechanical – Operating Temperature -22° to +140° F, -30° to +60° C. Lithium battery required for temperatures below -4°F (-20°C).
Mechanical – Display Graphics LCD
Mechanical – Housing Shock & water resistant molded urethane
Mechanical – Hot Stick Mounting Universal chuck adapter (Hot stick not included)
Mechanical – Battery 9V Alkaline or Lithium

User Manuals

Qualstik Operators Manual

SKU: SEN-8-061-XT-PLUS
Models: Qualstik Plus