{"product_id":"qualstik","title":"Qualstik Live-Line Power Quality Meter","description":"\u003cp\u003eThe Qualstik Power Quality Meter has been developed specifically for measurement of four important items of power quality in the electric utility industry. These are Current, True Power Factor, Total Harmonic Distortion and the Direction of Current Flow.\u003c\/p\u003e\n\u003cp\u003eThe Qualstik is an excellent survey instrument for locating problem areas for comprehensive testing. The SensorLink patented amp sensor does not use magnetic materials and has no moving parts. The opening of the sensor is electronically closed and external currents are electronically rejected. The True Power Factor is calculated by measuring the electric field in comparison with the current reported from the amp sensor.\u003c\/p\u003e\n\u003cp\u003eThe Qualstik is not position sensitive, just slip it over a conductor and touch the electrode in the bottom of the fork to the line. The meter will store and calculate the three measurements within 10 seconds. The current reading is shown on one line of the display while the power factor and THD readings share the other line. The direction of current flow indication shows below the other readings on the display.\u003c\/p\u003e\n\u003cp\u003eThe housing of the Qualstiks are made of urethane and built to operate safely even in severe utility environments. They are resistant to shock, water repellent, and unsusceptible to flame. They also operate in a wide temperature environment.\u003c\/p\u003e\n\u003cp\u003eThe Qualstik is an excellent survey tool to assist determining placement of power factor correction devices as well as identifying other power quality problems. \u003c\/p\u003e\n\u003cp\u003eThe QualstikPlus is designed to store up to eight sets of readings, which the user is then able to delete on the instrument.\u003c\/p\u003e\n\u003ch3\u003eSpec Sheets\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0743\/6959\/7761\/files\/Qualstik_Plus_Datasheet_0.pdf?v=1793207250\" rel=\"noopener\" style=\"color: #0000ff; text-decoration: underline;\" target=\"_blank\"\u003eView Qualstik Plus Specification\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; max-width: 100%; overflow: hidden;\"\u003e\n\u003ctable style=\"width: 100%; max-width: 100%; border-collapse: collapse; table-layout: fixed; font-size: 13px;\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 42%;\"\u003e \u003ccol style=\"width: 58%;\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 5px; text-align: left; white-space: normal; overflow-wrap: break-word;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 5px; text-align: left; white-space: normal; overflow-wrap: break-word;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e8-061 XT PLUS \/ 8-062 PLUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003eQualstik Plus \/ Wide Jaw Qualstik Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eSensor Opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e8-061 XT PLUS: 2.5 in, 6.35 cm\u003cbr\u003e8-062 PLUS: 3.86 in, 9.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e8-061 XT PLUS: 3.0 lbs, 1.37 kg\u003cbr\u003e8-062 PLUS: 3.5 lbs, 1.58 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eFrequency, 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e47 to 53 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eFrequency, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e57 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eMeasurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003eNine Readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eRange of Operation – True RMS Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e1-2000 A (5-2000A for the 8-062 PLUS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eRange of Operation – Power Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e0.01 lag to 0.01 Lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eRange of Operation – THD Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e1-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eRange of Operation – Current Flow Direction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003eAmps in or Amps Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eRange of Operation – Voltage phase to phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e600 Volts to 500kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eResolution – Amps 1-99.9A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eResolution – Amps 100-2000A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eResolution – Power Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e1.0 to .01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eResolution – THD Amps 0.1% to 10%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eResolution – \u0026gt; 10%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eAccuracy – Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e± 1%, ± 2 Counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eAccuracy – Power Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e±.01 from .71 lead to .71 lag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eAccuracy – THD Amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e±1% from 0 to 25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eEEC Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003eSuccessfully passed international test standards indicated by CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eMechanical – Controls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003eSingle button operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eMechanical – Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e-22° to +140° F, -30° to +60° C. Lithium battery required for temperatures below -4°F (-20°C).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eMechanical – Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003eGraphics LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eMechanical – Housing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003eShock \u0026amp; water resistant molded urethane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eMechanical – Hot Stick Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003eUniversal chuck adapter (Hot stick not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 5px;\"\u003e\u003cstrong\u003eMechanical – Battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 5px;\"\u003e9V Alkaline or Lithium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eUser Manuals\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0743\/6959\/7761\/files\/Qualstik_XT_WJ_Web_Manual-007_V01.pdf?v=1793207369\" target=\"_blank\" rel=\"noopener\" style=\"color: #0000ff; text-decoration: underline;\"\u003eQualstik Operators Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"SensorLink","offers":[{"title":"Qualstik Plus","offer_id":68085263401281,"sku":"SEN-8-061-XT-PLUS","price":1000.0,"currency_code":"CAD","in_stock":true},{"title":"Wide Jaw Qualstik Plus","offer_id":68085263434049,"sku":"SEN-8-062-PLUS","price":1000.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0743\/6959\/7761\/files\/3_6473a08a-77f9-432c-b1cb-67b0ba6d50f6.png?v=1793207036","url":"https:\/\/linestar.ca\/products\/qualstik","provider":"LineStar Utility Supply","version":"1.0","type":"link"}